Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Contact Us
  • Home
  • Benderlink Software

Benderlink for MiiC

Written by Michael Cone

Updated at January 29th, 2026

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • VTube Update Articles
  • VTube Technical Articles
    VTube General (STEP and LASER) VTube Reports VTube-LASER VTube Configuration and Maintenance VTube-STEP VTube Installation SOLIDWORKS Configuration VTube Videos VTube Cloud License Server VTube Communications
  • Benderlink Software
  • Benderlink Hardware
  • Bending Terminology
  • Partners
  • CNC Bender ProControl
  • Bender to XYZ
  • General Software Topics
  • Utility Software
  • Windows Technical Articles
    Cable Specs
  • Measuring Devices
    HEXAGON Articulated Arms Metronor
  • TubeCAD
  • Benderlink Update Articles
  • Uncategorized
+ More

Table of Contents

MiiC Control Setup for RS-232 Communications How to Put a MiiC into Remote Communications Mode and Start Communications Long Distance Communication Hardware Details on File Data Handled by Benderlink Benderlink for MiiC Project File Format Supravision File Data Format Can Benderlink handle both XYZ and Bender Data in Supravision? Any other data in Supravision format? What happens when the Supravision data file is imported?

 

Connect to MiiC Benders, edit data, send solid models, save the MiiC data to your computer using the MiiC BSC protocol.

Features

CONNECTS TO MEASURING CENTERS TO ENABLE CORRECTIONS LOOPS

Connect to VTube-LASER with a using a network connection.

Connect to a Laservision arm using the Eaton Leonard Legacy Current Loop protocol.

This feature allows the measuring center to make direct corrections to the MiiC bender data to adjust the machine automatically.

PROVIDES CLEAR COMMUNICATION STATUS FEEDBACK

The Benderlink user-interface displays the status of communications. The program provides feedback for the type of measuring center being used, the status of communications, and translation status.
EDIT BENDER DATA

Enter and modify XYZ data, convert to PRB (bender) data, modify PRB data. MiiC parameter data and production data variables can also be edited.
SAVE/LOAD MIIC DATA FILES MiiC data can be saved and recalled from your hard drive, backed up to CD-ROM, network, or anywhere.
SAVE/LOAD SUPRAVISION FILE DATA FOR CONVERSION TO MIIC Supravision files can be imported and converted to MiiC format. MiiC data can also be exported to Supravision files.

Using Benderlink for MiiC to Replace Tape and Floppy Disk Drives

MiiC tape and floppy drives, like all electromechanical devices, tend to wear out over time. Customers say that they are not easily replaced with the new tape drives as the tape drives are becoming more difficult to find. The MiiC benders are outlasting the MiiC tape drives.

Customers are using our Benderlink for MiiC software to solve the problem of the aging tape drives. Benderlink for Miic is excellent for data storage. The data that is transferred from the MiiC is stored on the computer hard drive.

In one application we installed, there are four MiiC benders connected through wireless connection to a central Benderlink computer. The customer sends Supravision files created by Tubecad to a central location on the network. The MiiC operators then import the Supravision data into Benderlink for MiiC, then send the new data out to one of the four MiiC benders.

After the program is completely setup (with wedges and options), the operator then uses Benderlink for MiiC to transfer the final setup to the disk of the Benderlink computer.

MiiC Control Setup for RS-232 Communications

The MiiC controls don't come with communications enabled by default, so this option needs to be enabled by the MiiC technicians.

  • The MiiC BSC protocol should be enabled.
  • The MiiC control needs a physical DB25 port installed if it is not present. These come on plug in cards.
  • The protocol should use a communications parity of NONE.

How to Put a MiiC into Remote Communications Mode and Start Communications

STEP 1 - TAPE / PRINT

On the MiiC keypad, press TAPE / PRINT button:

STEP 2 - PIPE READER INTERFACE

Enter the PIPE READER INTERFACE. Pres "5" or "7" depending on the bender model:

STEP 3 - FILE NUMBER

Choose a File number 1 through 4 to indicate which File in memory Benderlink should communicate with:

STEP 4 - BENDERLINK

In Benderlink, select the bender number and start the communications:

Long Distance Communication Hardware

For cable distances greater than 50 feet, we recommend that you use our Benderlink Ethernet Module technology.

Details on File Data Handled by Benderlink

Benderlink for MiiC handles to file formats:

  1. Benderlink for MiiC (native file format to Benderlink)
  2. Supravision File (Software used in Romer measuring centers)

These files can be loaded through menu commands or using drag and drop of files.

Benderlink for MiiC Project File Format

Benderlink for MiiC also has our own file format designed for storage of all the data on the MiiC control. (The Supravision file format will not save all options in the MiiC data - only the basics listed above.)

Supravision File Data Format

Can Benderlink handle both XYZ and Bender Data in Supravision?

YES to BOTH - if they are present. The Supravision file format can have either XYZ data or BENDER data or BOTH.

The XYZ data can be used to invert the bend program or recalculate the straights in the bender data.

Even though the MiiC BMC protocol allows XYZ data to be sent to the MiiC, not all MiiCs will actually take the XYZ data in.

MiiC reliably takes in the most important data: The PRB (bender) data.

Any other data in Supravision format?

The SV file format also includes other items that may be in the file. For example, the part number, the tube diameter, the tube length are all usually in the file. This data is imported into Benderlink for MiiC also.

What happens when the Supravision data file is imported?

When Benderlink for MiiC imports the Supravision data, a conversion to the MiiC bender format is automatic. This allows the operator to view, further edit, and then send the imported data directly to a MiiC bender.
connector interface

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • How to Use the Benderlink for Chiyoda KEINS Password Manager
  • How To Diagnose and Fix Benderlink Path Errors
  • Cable Spec 33 - Simulate the Premier Bender side of a current loop connector Amp Circular to RJ-45 - inside of Benderlink Ethernet Module

Copyright 2026 – Advanced Tubular Technologies.

Knowledge Base Software powered by Helpjuice

Expand