CRIPPA SVNet Communications with VTube
Table of Contents


| This page describes the setup and use of the VTube to CRIPPA Supravision file communications for newer CRIPPA benders with the SVNET protocol. Descriptions for VTube-STEP and VTube-LASER are included. Some of these steps require technical assistance from a CRIPPA or Advanced Tubular Technologies technician to complete the connection. |
About VTube-STEP and VTube-LASER
|
|
|
STEPS TO SETUP FOR COMPUTER NETWORKING
These steps will require connecting two computers using network cabling. Some of the steps require CRIPPA or Advanced Tubular technical assistance.
STEP 1: Plug in Cable 2 In The CRIPPA HMI Computer
|
![]()
|
STEP 2: Plug The Other End of the Cable Into A Network Switch
|
![]() |
STEP 3: Allow a Technician to Configure the CRIPPA and the VTube Computers
![]()
These steps require technician-level assistance from CRIPPA or Advanced Tubular Technologies.
|
The technician will...
|
STEP 4: Enable Supravision Communications in the CRIPPA UII Interface
|
The technician will...
|
STEP 5: Test the Network Connection on the VTube Computer
|
Test the network connection at the VTube computer using the Windows File Explorer.
|
![]() ![]()
|
BENDERLINK SETUP STEPS FOR VTUBE-STEP AND VTUBE-LASER
You can perform this setup from VTube-STEP or VTube-LASER. The steps are identical in both.
STEP 1: Enter the SYSTEM OPTIONS Menu in VTube
|
![]() |
STEP 2: Setup the Benderlink Network Grid for CRIPPA Supravision Network Protocol
|
![]() |
HOW TO SEND AND RECALL DATA FROM VTUBE-STEP AND VTUBE-LASER

How to SEND MASTER XYZ Data to the CRIPPA Control from VTube-STEP
You can import data or models into VTube-STEP then send the calculated LRA bender data to the CRIPPA bender using the VTube BENDER OUTPUT menu.
STEP 1 - Use the BENDER OUTPUT Menu
|
![]() ![]() |
STEP 2 - SAVE the Data at the CRIPPA UII Software
| CRIPPA will ask for confirmation to update when it receives the incoming data. Say "Yes". The YBC data will change to match the data that was sent from VTube. You can compare a few values to be sure the data was updated properly. |
![]() |
STEP 3 - SAVE and COMPILE
|
![]() |

How to SEND MASTER LRA Data to the CRIPPA Control from VTube-LASER
You can also send the new LRA data from the VTube-LASER BENDER SETUP menu to the CRIPPA bender using the VTube Bender Output menu.
STEP 1 - Enter the BENDER SETUP menu in VTube-LASER
| Press the "BENDER SETUP button in the Navigation Pane. | ![]() |
STEP 2 - Choose the BENDER NUMBER
| Set the correct bender number at the top of the window. You can select up to 100 different benders. You should see a CRIPPA SupravisionNET icon at the top left corner of the screen. The Bender Protocol should say "CRIPPA SVnet". (This assumes that you have already configured VTube's Benderlink in the Systems Options as described in the previous VTube-STEP section.) |
![]()
|
STEP 3 - Setup the Bender Setup Data in this WINDOW
|
This is for a first-time setup for a new part. Data in this window is separate from data in the main VTube-LASER window, so it is necessary to bring data into this window when performing the first-time setup of a part. This ensures that the correct data is sent to the CRIPPA.
|
![]()
|
STEP 3 - Send data to the CRIPPA BENDER
|
![]() |
STEP 4 - The Send to Bender Complete Window
| A window indicating that data was sent should appear for a few seconds and disappear automatically. | ![]() |
STEP 5 - SAVE the Data at the CRIPPA UII Software
| Move to the CRIPPA control. CRIPPA will ask for confirmation to update when it receives the incoming data. Say "Yes". If you don't see this green banner, then communications did not occur. You will need to trouble-shoot the connection to make it work. The YBC data will change to match the data that was sent from VTube. You can compare a few values to be sure the data was updated properly. |
![]() |

How to SEND CORRECTION Data to the CRIPPA Control from VTube-LASER
STEP 1 - Bend the Tube
| Bend the tube in the CRIPPA. | ![]() |
STEP 2 - Measure the tube with VTube-LASER
| Measure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape. In the screenshot on the right, the red on the top left shows that the first END "A" LENGTH is out of tolerance. The length is 0.054" long. Also, the red cell in the tangent point grid on the lower right shows that the measured tube centerline shape is out-of-tolerance because the deviation is 0.121". Also - VTube is very visual. The solid model on the right shows exactly where the part is out is exceeding the tolerance. Click on the image to zoom in to see the values. |
![]()
|
STEP 3 - Enter BENDER SETUP
| Click on the BENDER SETUP button in the Navigation Pane. | ![]() |
| For dual-screen systems, VTube-LASER will let you press the Switch Screens button in the upper right corner to move the Bender Setup window to the second screen like this: See VTube-LASER Multiple Screen Support for more information about this feature. |
![]() ![]() |
STEP 4 - Choose the BENDER NUMBER
| Set the correct bender number at the top of the window. You can select up to 100 different benders. You should see a CRIPPA icon at the top left corner of the screen. The Bender Protocol should say "CRIPPA SupravisionNET". (This assumes that you have already configured VTube's Benderlink in the Systems Options as described in the previous VTube-STEP section.) |
![]() |
STEP 5 - RECALL CRIPPA YBC data
| Be sure that the Part Number value is the same as the part name in the CRIPPA control. The CRIPPA will not return data unless it recognizes the part number. Remember that the CRIPPA UII will only return data from the part that is SAVED TO THE DISK. It will not return UNSAVED data in the UII screen. In the Bidirectional Communication menu on the right, click on RECALL. RECALLING data is a critical step during correction. If a RECALL is not performed before a CORRECTION, then VTube may not be able make adjustments to the correct starting YBC data. Be sure to perform this step before performing the CORRECTION step below. |
![]()
|
STEP 6 - OPTIONAL STEP - You Can Manually Change the ADJUSTMENT Values
| You can manually change the ADJUSTMENT values before sending corrections if you want to. Some users like to set the first and last Length adjustment to zero in order to keep the start position of the carriage in the same place - for when they have extra length on the ends. If you want to, it is even possible to invert the rotation direction to keep the tube from hitting the bender during rotations. |
![]() |
STEP 7 - Send the CORRECTION Values to the CRIPPA
| Click on AUTO SEND. This will send the ORANGE columns to the CRIPPA bender. To be sure that a RECALL has recently been performed, VTube will show a CRIPPA CORRECTIONS NOTES as a reminder. |
![]() |
STEP 8 - The SEND ADJUSTED Window
| A window should appear for a few seconds indicating that the Send to the Bender is complete. |
![]()
|
STEP 9 - SAVE the New Data at the CRIPPA UII Software
| Move to the CRIPPA control. CRIPPA will ask for confirmation to update when it receives the incoming data. Say "Yes." If you don't see this green banner, communications did not occur. You'll need to troubleshoot the connection to make it work for you. The YBC data will change to match the data that was sent from VTube. You can compare a few values to be sure the data was correctly updated. The VTube-LASER SEND will only update the UII data on the CRIPPA screen. (Remember: CRIPPA only returns data from the file - see "RECALL" above.) This new data that the CRIPPA UII screen just received from VTube-LASER must be SAVED to the disk and compiled to take effect. |
![]()
|
STEP 10 - REPEAT STEPS 1 THROUGH 9
| Bend the tube in the CRIPPA (Step 1), then measure it again (Step 2) and follow the rest of the steps until the part is within tolerance. | ![]() |



















.png)