Recommended FARO Scanner Settings

Written by Michael Cone

Updated at January 27th, 2026

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • VTube Update Articles
  • VTube Technical Articles
    VTube General (STEP and LASER) VTube Reports VTube-LASER VTube Configuration and Maintenance VTube-STEP VTube Installation SOLIDWORKS Configuration VTube Videos VTube Cloud License Server VTube Communications
  • Benderlink Software
  • Benderlink Hardware
  • Bending Terminology
  • Partners
  • CNC Bender ProControl
  • Bender to XYZ
  • General Software Topics
  • Utility Software
  • Windows Technical Articles
    Cable Specs
  • Measuring Devices
    HEXAGON Articulated Arms Metronor
  • TubeCAD
  • Benderlink Update Articles
  • Uncategorized
+ More

Table of Contents

FARO Scanner Settings for VTube-LASER FARO Quantum X FaroArm Series Older FARO Scanners Filters OFF Scan density depends on the diameter. FaroArm Manager Software Manual

FARO Scanner Settings for VTube-LASER

This is a guide for FARO scanner setup with VTube-LASER. The values can be adjusted in the FaroArm Manager software.

FARO Quantum X FaroArm Series

  • Using AUTOMATIC exposure and choose "Normal".

 

Use Automatic Exposure

 

Older FARO Scanners

The diagram shows the best exposure settings with the different older versions of FARO scanners when measuring tube shape.

In some cases, the older version scanners can use AUTOMATIC modes, but the cylinder calculation is not as reliable in these modes.

For version 2 and version 3 scanners, passing the 4-level cylinder fit-test in VTube-LASER 2.8 or newer when scanning tubes is almost impossible. In this case, the only solution is to use FIXED mode in the FARO Laser Line Probe Control window.

Filters OFF

  • Always turn the FILTERS OFF (especially the reflective and movement filters)

Scan density depends on the diameter.

  • For large diameters, 1/16 is good.
  • 1/4 or 1/2 is good for smaller diameters.
  • Aim the laser at the diameter and observe the result in the viewport. Be sure there are plenty of points along the diameter surface.
 

FaroArm Manager Software Manual

You can download the FaroArm Manager manual here.

faro scanner

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • HEXAGON RDS RS5 Scanner Setup Recommendations - Red Laser
  • VTube-LASER Shallow Bend Measure Process
  • FARO and the Windows RPC Service and RPC Server Errors

Copyright 2026 – Advanced Tubular Technologies.

Knowledge Base Software powered by Helpjuice

Expand