Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Contact Us
  • Home
  • VTube Update Articles

VTube Update History 4.3 - December 2024

Written by Michael Cone

Updated at January 29th, 2026

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • VTube Update Articles
  • VTube Technical Articles
    VTube General (STEP and LASER) VTube Reports VTube-LASER VTube Configuration and Maintenance VTube-STEP VTube Installation SOLIDWORKS Configuration VTube Videos VTube Cloud License Server VTube Communications
  • Benderlink Software
  • Benderlink Hardware
  • Bending Terminology
  • Partners
  • CNC Bender ProControl
  • Bender to XYZ
  • General Software Topics
  • Utility Software
  • Windows Technical Articles
    Cable Specs
  • Measuring Devices
    HEXAGON Articulated Arms Metronor
  • TubeCAD
  • Benderlink Update Articles
  • Uncategorized
+ More

Table of Contents

Version 4.3 Build 1723, December 21, 2024 1 - UAC allows for project file overwrite protection. Version 4.3 Build 1721, December 18, 2024 1 - We enhanced the Project Default State Files list to allow for saving the current project state to a default state in the list. 2 -The Project menu in System Options was reorganized for better logic. There is a new Back/Restore Configuration tab that is now separate from the Project Default State tab. Version 4.3 Build 1720, December 16, 2024 1 -The M-Scan interface was fine-tuned. 2 -The acquisition and accept buttons can be swapped based on user preferences. Version 4.3 Build 1719, December 12, 2024 1 - Enhancements for the M-Scan interface were made. Values were added to the "vtube local settings.cfg" file to fine-tune the interface. Version 4.3 Build 1717, December 11, 2024 1 - VTube-LASER now supports the Metronor M-Scan system. Version 4.3 Build 1716, December 10, 2024 1 - New save multiple default project states to a list in System Options. 2 - Select Space Object row when build to Space objects. 3 - Added Delete Selected Rows to Assembly Popup Version 4.3 Build 1713, December 6, 2024 1 - A Select Mode error dialog could display in VTube-LASER when measured data was being built from a measure. Version 4.3 Build 1710, December 2, 2024 1 - Several enhancements were made to the Bend Plane Clock Tool. 2 - The Bend Plane Clock data log can be output to a report using the new report token "BendPlaneClockLog."

Version 4.3 Build 1723, December 21, 2024

1 - UAC allows for project file overwrite protection.

This means you can configure and control whether a user can overwrite a VTube project file.

Your browser does not support HTML5 video.

Version 4.3 Build 1721, December 18, 2024

1 - We enhanced the Project Default State Files list to allow for saving the current project state to a default state in the list.

2 -The Project menu in System Options was reorganized for better logic. There is a new Back/Restore Configuration tab that is now separate from the Project Default State tab.

Version 4.3 Build 1720, December 16, 2024

1 -The M-Scan interface was fine-tuned.

2 -The acquisition and accept buttons can be swapped based on user preferences.

Version 4.3 Build 1719, December 12, 2024

1 - Enhancements for the M-Scan interface were made. Values were added to the "vtube local settings.cfg" file to fine-tune the interface.

a - Milliseconds Between Stripes Idle - Nikon Scanner=100

b - Milliseconds Between Stripes Scanning - Nikon Scanner=50

c - Milliseconds Between Stripes Inside Server - Nikon Scanner=100

d - Milliseconds No Motion To Automatic Acquisition Button Up - Nikon Scanner=2000

e - Millimeter Threshold For No Motion To Automatic Acquisition Button Up - Nikon Scanner=1

Version 4.3 Build 1717, December 11, 2024

1 - VTube-LASER now supports the Metronor M-Scan system.

See the M-Scan page for more information.

Version 4.3 Build 1716, December 10, 2024

1 - New save multiple default project states to a list in System Options.

2 - Select Space Object row when build to Space objects.

3 - Added Delete Selected Rows to Assembly Popup

Version 4.3 Build 1713, December 6, 2024

1 - A Select Mode error dialog could display in VTube-LASER when measured data was being built from a measure.

This was not helpful, and it was removed/fixed.

Version 4.3 Build 1710, December 2, 2024

1 - Several enhancements were made to the Bend Plane Clock Tool.

Now, VTube-LASER can show the distance along the straight from the intersection, tangent point, or midpoint in a Z axis.

We also added a Wall thickness calculator.

2 - The Bend Plane Clock data log can be output to a report using the new report token "BendPlaneClockLog."

 

vtube update

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • How to Install a VTube-LASER or VTube-STEP Update
  • VTube-STEP and VTube-LASER: How to Enter LRA Data with 360-Degree Rotations
  • VTube-LASER GD&T Perpendicularity with End Trim Profile

Copyright 2026 – Advanced Tubular Technologies.

Knowledge Base Software powered by Helpjuice

Expand