VTube Update History 4.1 - June 1, 2023 - July 5, 2023
Table of Contents
This page contains information about older versions of VTube-STEP and VTube-LASER. If you want information about the latest version, see the VTube Update History page.
See this PDF document for older updates: VTube v4 Update History.pdf
Version 4.1 - Build 1275, July 5, 2023
Note: If you use Bend Profile Inside-Radius measuring, upgrade version 4.2, build 1279 or newer is critical.
Change: When a user edits values inside the Absolute LRA menu and the "Automatic Calc Cut Length" switch is ON, VTube will display a notice and then change the switch to OFF.
This is the dialog that displays. |
The cut length value is usually predetermined for entering Absolute bender data. It should not be recalculated when using this menu because the calculations rely on a known and fixed cut length. ![]() ![]() |
Version 4.1 - Build 1274, June 30, 2023
Note: If you use Bend Profile Inside-Radius measuring, upgrade version 4.2, build 1279 or newer is critical.
Fixed: Automatic switch from scanner to tactile when exiting shallow bend measuring |
The automatic switching from scanner to ball probe and back is fixed so that the process will correctly switch back to scanner or probe when switching to the cylinder or end scan measure coming out of the shallow bend measuring. |
New: HEXAGON RA8 arms automatic switching between scanner and tactile
|
RA8 HEXAGON ScanArms scanner selection is now controlled by VTube-LASER - just like for FARO and Kreon arms. ![]() |
New: The Toggle Laser button is now available for the HEXAGON RS8 arms. |
![]() |
Fixed: End Scan Flier Filter will always return at least one point for end scans. |
![]() |
New Notepad++ 8.5.4 |
![]() |
Version 4.1 - Build 1272, June 22, 2023
Note: If you use Bend Profile Inside-Radius measuring, upgrade version 4.2, build 1279 or newer is critical.
New: Control the setup for automatic switching between laser and ball probe during shallow bend measure. (This feature is useful for FARO and Kreon arms.)
|
The new value is controlled inside the Measure Setup Laser menu. ![]() This new setup value is helpful for scan arms that allow the program to switch between laser and ball probe modes - like FARO and Kreon. |
|||
| The help window displays in the lower right corner indicating that it either has switched probe modes (FARO and Kreon), or requests that the operator switch probe modes (HEXAGON). When the "Shallow Bends Scans User Laser by Default" is turned OFF, VTube-LASER will automatically switch from the laser to the ball probe in FARO and Kreon arms without the user pressing a button on the screen. For the HEXAGON arms, VTube-LASER suggests switching between laser scanner and ball probe, then lets the user choose to switch using the toggle button. |
![]()
|
Version 4.1 - Build 1270, June 19, 2023
This build has a fix for the Part Setup Default Tolerance value copy. All the intersection columns now receive the value (X, Y, Z, and 3D columns of the intersection deviations. |
This was the before-fix result of the copy:
This is the after-fix result of the copy:
|
Version 4.1 - Build 1269, June 16, 2023
VTube-STEP can now import Tracto-Technik PIPEFAB B CTI files. |
This file format includes centerline XYZ and bend radii. No diameter is included in the import. ![]() ![]() Note: The CTI file structure is very complex. We are still determining if every CTI file will import. |
Version 4.1 - Build 1266, June 9, 2023
We fixed a bug for Path Manager where the path selected was not being used when exiting the Path Manager. |
![]() |
We changed the default report templates so that reports that show rotation corrections clearly state if they are using CCW-positive or CW-positive rotation corrections. |
![]() |
Version 4.1 - Build 1265, June 8, 2023
VTube-LASER now has separate +/- default values for the end tolerances in the Inspection menu.
|
It is now possible to preset the end length default tolerances in cleared projects - then save the setup to the default project in System Options. ![]() Other notes:
|
A change was made to the installation file to allow it to test for the correct Visual C++ Redistributable library. |
![]() If you still get this error during installation, then use File Explorer to browse to the VTube folder (c:\Program Files (x86)\VTube..., then manually run the "vcredist_x86.exe" program. (You can also contact us by clicking on the Contact Us button at the top of this page.) |
Version 4.1 - Build 1264, June 5, 2023
The FARO mode toggle laser button no longer disappears at the start of a measure. |
![]() |
The user guide window shows a more specific message when Dual Cylinder Fit measures are out of tolerance.
|
Old message: ![]() New message: ![]() |
VTube-LASER now adds a suggestion to the user guide window when the DCF fails and the bend angle is very near the threshold programmed. |
The suggestion is to increase the threshold angle and try again so that VTube will treat the issue as a shallow bend angle. ![]() |
The Dual Cylinder Fit Shallow Bend Handling Threshold is now increased from 1.0 to 5.0 degrees. |
![]() |
Version 4.1 - Build 1263, June 2, 2023
The CRIPPA SVNET communications protocol was fine-tuned to fix a recurring issue where the CRIPPA control would not respond to commands from VTube-LASER. |
This update impacts VTube-LASER customers with CRIPPA benders.
This is an example folder with a non-CRIPPA SVNET command/data and netsv event log files:
This is an example with a CRIPPA SVNET command/data file only. No netsv file is built for the CRIPPA protocol.
|
Version 4.1 - Build 1262, June 1, 2023
VTube-LASER: MOVE THE PART is enhanced so users can move a part with only one or two bends |
Previous versions of VTube-LASER required that the measured tube have three bends for moving the tube in the middle of a measure. Now move part works with even a one-bend part. |
VTube-LASER: The MOVE THE PART window is redesigned for clarity |
The window was redesigned to show the “Start At” straight number to clarify to the operator which straight should be measured after the part is moved.
|
VTube-LASER: New open file dialog controls were added for the User Turbo screen setup.
|
These controls allow more flexibility in how open file dialogs display for users on that screen. The UAC controls are in System Options in the UAC menu.
|
| See a video for how the new UAC open file dialog setup works. | |
The redesigned File Setup menu inside System Options has new options for more choices in how VTube opens projects or imports files. |
The new choices are:
The values are set separately for both Open VTube Projects and Import VTube Files. (click the image to make it larger)
|
The Pass/Fail Attributes variables in the Inspection menu are now included in the Measure Setup Batch Change.
|
|
New Notepad++ 8.5.3 |
|
Links to Previous Versions
See this document for older updates: VTube v4 Update History.pdf
.png)































