Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Contact Us
  • Home
  • VTube Update Articles

VTube Update History 4.4 - September, 2025

Written by Michael Cone

Updated at January 29th, 2026

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • VTube Update Articles
  • VTube Technical Articles
    VTube General (STEP and LASER) VTube Reports VTube-LASER VTube Configuration and Maintenance VTube-STEP VTube Installation SOLIDWORKS Configuration VTube Videos VTube Cloud License Server VTube Communications
  • Benderlink Software
  • Benderlink Hardware
  • Bending Terminology
  • Partners
  • CNC Bender ProControl
  • Bender to XYZ
  • General Software Topics
  • Utility Software
  • Windows Technical Articles
    Cable Specs
  • Measuring Devices
    HEXAGON Articulated Arms Metronor
  • TubeCAD
  • Benderlink Update Articles
  • Uncategorized
+ More

Table of Contents

Version 4.4 - Build 1905, September 26, 2025 NEW: BPC Search Box NEW: BPC - Unlimited Channel Count Version 4.4 - Build 1904, September 23, 2025 FIX: Windows redraws VTube correctly when moving to other screens. Version 4.4 - Build 1903, September 22, 2025 NEW: The Metronor M-Scan 120 connection user interface has been improved based on new experiences gained from using the M-Scan 120. Version 4.4 - Build 1902, September 22, 2025 NEW: Point Cloud transformation and translation Version 4.4 - Build 1901, September 19, 2025 NEW: Tube Data Storage can now be disabled in VTube to save memory. NEW: You can now choose not to save Tube Data Storage information in a project to the project file. FIX: When creating a new Space Object in the control, the grid updates with the added object. NEW: The Cut Plane grid now has a popup menu that allows users to more easily change the Active states of each cut plane, and allows users to quickly delete cut planes. Version 4.4 - Build 1900, September 18, 2025 NEW: VTube-LASER can now create and measure POINT Space Objects using a new "Create POINT Space Object" control window. New: The Create control allows you to select any point from the point cloud to store as a space object for inspection and reporting. New: The Space Objects control shows space object points and metrics controlling tolerances and reporting. Version 4.4 - Build 1889, September 10, 2025 1 - FIX: The Nikon NMAPI Server Console will always be displayed and minimized to the taskbar. 2 - FIX: The Milliseconds pause times for the NMAPI setup are now saved correctly to the global configuration file. 3 - NEW: The default NMAPI server pause times are now 100 ms. 4 - NEW: VTube-LASER will warn you if the NMAPI Server Loop Interval is adjusted to below 100 ms. 5 - FIX: The End Measure Type in Measure Setup is now stored in the project files. 6 - NEW: The End Measure Type title names have been changed to End A Trim Profile Type and End B Trim Profile Type. Version 4.4 - Build 1888, September 5, 2025 1 - NEW Export/Import functionality for the Springback Table 2 - NEW GD&T OD Measured Values of Positions Grid 3 - NEW SAE J2551-1 OD Sleeve Datum Feature grid. 4 - New Pass/Fail Attributes for GD&T 5 - NEW SAE J2551-1 Setup Grid 6 - NEW Default Tolerance Control Window

Version 4.4 - Build 1905, September 26, 2025

NEW: BPC Search Box

This was requested by a customer. It allows for easy searching through bender channels.

NEW: BPC - Unlimited Channel Count

Bender Project Control previously could only use up to 100 channels. Now the number can be increased to any number of channels.

This window shows VTube-LASER using 200 channels.

Version 4.4 - Build 1904, September 23, 2025

FIX: Windows redraws VTube correctly when moving to other screens.

Version 4.4 - Build 1903, September 22, 2025

NEW: The Metronor M-Scan 120 connection user interface has been improved based on new experiences gained from using the M-Scan 120.

After using the M-Scan 120 regularly, the UI has been updated.

Version 4.4 - Build 1902, September 22, 2025

NEW: Point Cloud transformation and translation

The transformation and translations apply to any displayed buckets. Any bucket that is either displayed or active is included since active points are also displayed. Any point that is ON in will be transformed/translated.

Your browser does not support HTML5 video.
This check box allows users to transform DISPLAYED point cloud buckets when the MASTER, MEASURED, or MEASURED-ALIGNED tubes are transformed.
This check box allows users to translate DISPLAYED point cloud buckets when the MASTER, MEASURED, or MEASURED-ALIGNED tubes are translated.

Version 4.4 - Build 1901, September 19, 2025

NEW: Tube Data Storage can now be disabled in VTube to save memory.

Two new check boxes were added.

1) Tube Data Storage is Enabled: This allows users to choose whether or not to enable Tube Data Storage. If this is checked, users will save memory but lose the ability to use Measured Tube Average
2) Tube Data Storage File Storage is Enabled: This allows users to choose whether or not to save parallel Tube Data Storage (TDS) files.

NEW: You can now choose not to save Tube Data Storage information in a project to the project file.

This new check box allows users to decide whether or not to save the imported model with the project file.

FIX: When creating a new Space Object in the control, the grid updates with the added object.

A line will now appear in the Space Objects list when users enter a new Space Object

Your browser does not support HTML5 video.

NEW: The Cut Plane grid now has a popup menu that allows users to more easily change the Active states of each cut plane, and allows users to quickly delete cut planes.

All changes to the but plane list can be undone, so VTube-LASER does not ask for confirmation during these changes.

Your browser does not support HTML5 video.

Version 4.4 - Build 1900, September 18, 2025

NEW: VTube-LASER can now create and measure POINT Space Objects using a new "Create POINT Space Object" control window.

The control is added to the Space Objects menu in VTube-LASER.

New: The Create control allows you to select any point from the point cloud to store as a space object for inspection and reporting.

  • Select one point in the point cloud, then create a new POINT space object.
  • Select multiple points in the point cloud, then create a POINT space object located at the CENTROID of all the points.
  • The nominal and measured point values are set to the same starting location when creating a NEW space object point.
  • The location for either Nominal or Measured can be manually changed.
  • Snap the point to any space object plane.
  • Offset the space object point along the X, Y, or Z axes by any value.
  • Copy any measured point in the point cloud to either the nominal or measured point section for a space object point.
Your browser does not support HTML5 video.

New: The Space Objects control shows space object points and metrics controlling tolerances and reporting.

Turn the nominal or measured point on or off in the viewport.

Set the name for the point.

Change the point color.

Set up reporting and qualification in the General Metrics grid.

The point models are a complex geometry made up of:

  1. A point entity.
  2. Three axes lines.
  3. A sphere (for easy visual location).

The point spheres are always 1 mm in diameter.

Select and delete the sphere to select the actual point entity in the center of the Space Object model.

Version 4.4 - Build 1889, September 10, 2025

1 - FIX: The Nikon NMAPI Server Console will always be displayed and minimized to the taskbar.

It must be visible so the Nikon scanner editor can be displayed without locking up the system. The console is displayed in a command window, then minimized to the taskbar.

 

2 - FIX: The Milliseconds pause times for the NMAPI setup are now saved correctly to the global configuration file.

The values were not saved in previous versions of VTube.

3 - NEW: The default NMAPI server pause times are now 100 ms.

This keeps the LK Metrology (Nikon) scanner from locking up the Metronor software. (The previous default times were 50 ms.)

4 - NEW: VTube-LASER will warn you if the NMAPI Server Loop Interval is adjusted to below 100 ms.

5 - FIX: The End Measure Type in Measure Setup is now stored in the project files.

6 - NEW: The End Measure Type title names have been changed to End A Trim Profile Type and End B Trim Profile Type.

This clarifies the meaning of the values. They apply to End Profile measurements only.

Version 4.4 - Build 1888, September 5, 2025

1 - NEW Export/Import functionality for the Springback Table

  • Users can now export/import a Springback table that was made inside VTube. This can be transferred to other licenses of VTube or used in other software.

2 - NEW GD&T OD Measured Values of Positions Grid

  • This new grid allows users to qualify their parts with GD&T position tolerances

New token:

  • array_SAEJ2551Sleeve_MeasuredValueOfPosition

 

3 - NEW SAE J2551-1 OD Sleeve Datum Feature grid.

  • This grid shows the GD&T datum feature qualification on any length in a tube per the SAE J2551-1 specification.

New Tokens:

  • SAE_J25511_SLEEVE
  • array_SAEJ2551Sleeve_MeasuredValueOfPostion_OOT
  • array_SAEJ2551Sleeve_DatumFeatureName
  • array_SAEJ2551Sleeve_StraightNumber

4 - New Pass/Fail Attributes for GD&T

  • These new attributes can be checked on and added to a report for users to quickly identify if a part passes or fails inspection.

5 - NEW SAE J2551-1 Setup Grid

  • This new SAEJ2551-1 setup grid allows users to setup the sleeves, add tolerances and choose the anchor points. 

 

Your browser does not support HTML5 video.

6 - NEW Default Tolerance Control Window

  • This allows VTube to free up and clean up some UI space without slowing down the system.
  • We removed the scrollbox and replaced it with the new Control Window
  • Users can now set the default tolerances for multiple grids from the Control Window
vtube update

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • VTube Update History 4.4 - December, 2025
  • VTube Update History 4.4 - October 2025
  • VTube Update History 4.4 - November 2025

Copyright 2026 – Advanced Tubular Technologies.

Knowledge Base Software powered by Helpjuice

Expand